Most Recent Pins (15)
Daniel Heady
Solace Heating and Air inspected an air conditioning unit in Madison, Tennessee that had shut down due to high pressure. The technician found an outdoor fan malfunction and traced the problem to a loose factory-installed plug. After securing the connection, the unit resumed proper cooling.





Daniel Heady
A technician in White House, Tennessee repaired a split heat pump that was not cooling properly. The issue was caused by a tripped overflow switch in the drain pan. The drain system had two traps, so a vent was added to allow proper water flow and prevent future shutdowns.

Daniel Heady
Solace Heating and Air inspected a split heat pump system in Hendersonville, Tennessee after a cooling issue was reported. Technicians identified a leaking evaporator coil in the attic. The coil was under parts warranty. The team reviewed repair options and provided a detailed estimate for the necessary repairs.




Daniel Heady
Solace Heating and Air inspected an AC system in Nolensville, Tennessee, during a no-cool issue. The technician found low refrigerant and a leak in the evaporator coil. They showed the homeowner the source of the problem and provided a detailed repair estimate during a free second opinion visit.


Daniel Heady
Solace Heating and Air inspected two malfunctioning HVAC units at a hotel in Clarksville, Tennessee. Technicians identified grounded compressors in both systems. They documented the issue and sent repair estimates to the building’s business manager for review.




Daniel Heady
Solace Heating and Air inspected a non-working air conditioning system in Smyrna, Tennessee. Technicians identified a failed ECM blower motor and reviewed repair options with the homeowner. The homeowner requested a quote for a full unit replacement, which the team scheduled for the following Monday afternoon.





Daniel Heady
A technician in Hermitage, Tennessee inspected an upstairs HVAC unit that was not cooling. The system had lost refrigerant due to a leak in the outdoor coil. The technician identified the issue and discussed repair options with the homeowner.




Daniel Heady
Solace Heating and Air replaced a malfunctioning downstairs HVAC unit in White House, Tennessee. The system had low refrigerant and a leak at the evaporator coil. After reviewing options, the homeowner chose a full unit replacement to restore cooling.




Daniel Heady
Solace Heating and Air cleared a clogged drain line on an upstairs AC unit in White House, Tennessee. The technician reset a tripped in-line float switch and applied drain treatment to improve system flow and prevent future blockages.


Daniel Heady
Solace Heating and Air inspected a Trane package unit in Portland, Tennessee that was not cooling. The technician tested the system, diagnosed the cause of the malfunction, and reviewed available repair options with the homeowner.




Daniel Heady
Solace Heating and Air repaired a split heat pump in Hendersonville, Tennessee. The technician replaced a failed dual capacitor and confirmed the system resumed proper cooling. This service ensured reliable air conditioning by addressing a critical component failure in the unit.


Daniel Heady
Solace Heating and Air inspected a malfunctioning air conditioning system in White House, Tennessee. They identified a failed capacitor, installed a replacement, and tested the unit. After finding low refrigerant levels, they removed the new capacitor at the homeowner's request and scheduled a follow-up for a full unit replacement quote.




Garrett Hargrove
Solace Heating and Air replaced a leaking coil, performed a pressure test and vacuum, and confirmed system integrity before restoring cooling. This air conditioning repair service took place in Portland, Tennessee.


Daniel Heady
Solace Heating and Air diagnosed a failed ECM blower motor in Nashville, Tennessee. The technician presented repair and replacement options to the homeowner and arranged a replacement schedule.


Garrett Hargrove
Solace Heating and Air replaced a faulty suction line temperature sensor on an HVAC system in Murfreesboro, Tennessee. The thermostat had displayed an error code. After the replacement, the system resumed normal operation with no further codes.


Maps data from OpenStreetMap © OpenStreetMap