Most Recent Pins (21)
Daniel Heady
A technician in White House, Tennessee repaired a split heat pump that was not cooling properly. The issue was caused by a tripped overflow switch in the drain pan. The drain system had two traps, so a vent was added to allow proper water flow and prevent future shutdowns.

Daniel Heady
Solace Heating and Air inspected a split heat pump system in Hendersonville, Tennessee after a cooling issue was reported. Technicians identified a leaking evaporator coil in the attic. The coil was under parts warranty. The team reviewed repair options and provided a detailed estimate for the necessary repairs.




Daniel Heady
Solace Heating and Air inspected two mini split units in a basement in Springfield, Tennessee. One unit had a clogged drain, which was cleared. The other was low on refrigerant, and the homeowner is reviewing a replacement estimate.

Daniel Heady
Solace Heating and Air inspected an AC system in Nolensville, Tennessee, during a no-cool issue. The technician found low refrigerant and a leak in the evaporator coil. They showed the homeowner the source of the problem and provided a detailed repair estimate during a free second opinion visit.


Daniel Heady
Solace Heating and Air inspected two malfunctioning HVAC units at a hotel in Clarksville, Tennessee. Technicians identified grounded compressors in both systems. They documented the issue and sent repair estimates to the building’s business manager for review.




Daniel Heady
Solace Heating and Air replaced a malfunctioning downstairs HVAC unit in White House, Tennessee. The system had low refrigerant and a leak at the evaporator coil. After reviewing options, the homeowner chose a full unit replacement to restore cooling.




Daniel Heady
Solace Heating and Air cleared a clogged drain line on an upstairs AC unit in White House, Tennessee. The technician reset a tripped in-line float switch and applied drain treatment to improve system flow and prevent future blockages.


Jacob Weatherbee
Solace Heating and Air replaced a zone damper motor in Franklin, Tennessee. The technician restored full operation to the system, ensuring proper airflow and functionality. The HVAC unit now runs as expected.





Jacob Weatherbee
Solace Heating and Air replaced a faulty zone damper motor and restored proper HVAC operation in Franklin, Tennessee. The system now runs correctly, ensuring airflow is controlled as intended across all zones.





Daniel Heady
Solace Heating and Air cleared a clogged AC drain line and installed a time-release cleaning treatment in Antioch, Tennessee. The air conditioning unit now drains and cools correctly, restoring normal system function.


Daniel Heady
Solace Heating and Air inspected a Trane package unit in Portland, Tennessee that was not cooling. The technician tested the system, diagnosed the cause of the malfunction, and reviewed available repair options with the homeowner.




Daniel Heady
Solace Heating and Air diagnosed an air conditioning issue in Antioch, Tennessee. The technician found a clogged drain line tripping the sensor and a thermostat sending power to heat mode. They discussed repair options with the homeowner to restore proper system function.


Daniel Heady
Solace Heating and Air repaired a split heat pump in Hendersonville, Tennessee. The technician replaced a failed dual capacitor and confirmed the system resumed proper cooling. This service ensured reliable air conditioning by addressing a critical component failure in the unit.


Daniel Heady
Solace Heating and Air inspected a malfunctioning air conditioning system in White House, Tennessee. They identified a failed capacitor, installed a replacement, and tested the unit. After finding low refrigerant levels, they removed the new capacitor at the homeowner's request and scheduled a follow-up for a full unit replacement quote.




Jose Acevedo
Solace Heating and Air replaced a failed dual run capacitor on an air conditioning unit in Nashville, Tennessee. The system was blowing air but not cooling due to capacitor failure. Technicians restored cooling and recommended condenser coil cleaning and further repair estimates to prevent future strain on the system.





Garrett Hargrove
Solace Heating and Air replaced a leaking coil, performed a pressure test and vacuum, and confirmed system integrity before restoring cooling. This air conditioning repair service took place in Portland, Tennessee.


Daniel Heady
Solace Heating and Air diagnosed a failed ECM blower motor in Nashville, Tennessee. The technician presented repair and replacement options to the homeowner and arranged a replacement schedule.


Jose Acevedo
Solace Heating and Air replaced a failed capacitor to restore cooling on a zoned HVAC system in Nolensville, Tennessee. Technicians confirmed the furnace blower and condenser fan were working, but the compressor was inactive. After capacitor replacement, the system resumed normal operation. The customer also enrolled in an annual maintenance plan.





Garrett Hargrove
Solace Heating and Air replaced a condenser coil and completed a vacuum and pressure test to confirm no leaks. Technicians recharged the unit with the correct refrigerant amount. The HVAC system now runs correctly. Service completed in Brentwood, Tennessee.


Garrett Hargrove
Solace Heating and Air replaced a faulty suction line temperature sensor on an HVAC system in Murfreesboro, Tennessee. The thermostat had displayed an error code. After the replacement, the system resumed normal operation with no further codes.


Jose Acevedo
Solace Heating and Air provided a second opinion in Smyrna, Tennessee. The technician found a clogged indoor evaporator coil and blower assembly, along with a capacitor operating outside specifications. These issues reduced system efficiency. The technician quoted repair and cleaning options and provided a free estimate for system replacement due to the unit’s age.