Jackson, TN
Select Your Location
Jackson Jackson, TN. 38305 Set as my Location
Memphis Memphis, TN. 38134 Set as my Location
Nashville Nashville, TN. 37072 Set as my Location

Furnace Repair Near Jackson, TN

Furnace Repair Diagnostic

Schedule With Solace Plumbing, Heating, and Air Today!

Our Promise to You is to Perform the Correct Furnace Repair at an Honest Price

When you need Heating services, trust the experts at Solace Plumbing, Heating, and Air. Our experienced technicians are prepared with the knowledge and tools to quickly handle most Furnace issues.

When our Solace Plumbing, Heating, and Air technician arrives at your home, they will carefully explain your options, making sure you are fully informed before any repair or installation begins. With our expertise in servicing and repairing a variety of brands, you can rely on us for professional and dependable repairs.

Your satisfaction is our top priority, and we are dedicated to achieving it.

Solace Plumbing, Heating, and Air is Here for All of Your Heating Needs!

Get a System Quote.

Answer a few quick questions, get an instant on-screen quote, and schedule a home visit.

Solace Plumbing, Heating, and Air Offers Top-Quality Heating Services Near Jackson, TN

Call Today for Your Furnace Repair Service!
In Nashville, a technician is expertly repairing an outdoor air conditioning unit, carefully navigating the exposed wires and components.

Get the Quality, Reliable Service You Deserve

Solace Plumbing, Heating, and Air | Jackson, TNs Trusted Heating Professionals

We provide comprehensive installation, maintenance, and repair services for all your home Heating needs, regardless of the issue or season. Trust the reliable experts at Solace Plumbing, Heating, and Air for outstanding service and top-notch craftsmanship.

Solace Plumbing, Heating, and Air is proudly & professionally serving the greater Jackson, TN area.

Signs Your Furnace Requires Professional Repair From Solace Plumbing, Heating, and Air

Just because your home furnace technically works, does not mean it should go without repair. In fact, letting issues with your home furnace go unaddressed can lead to your furnace shutting down completely, and potentially even result in a replacement being required. Here are a few signs to look out for to know if your furnace requires professional repair:

Our team of experts in Jackson, TN are dedicated to providing specialized Heating services. Reach out to us today or conveniently schedule service through our contact form. Whatever your needs, count on our Jackson, TN specialists to deliver a hassle-free solution with upfront pricing and guaranteed customer satisfaction.

Have a question about your Furnace? Ask an expert from Solace Plumbing, Heating, and Air below for fast answers & get reliable service that your neighbors trust!

Schedule a Comprehensive Home Furnace Repair Near You in Jackson, TN

Facing Heating problems at home? Solace Plumbing, Heating, and Air is your trusted choice for repair services in Jackson, TN. Schedule your service today and get your repair underway!

Customer Reviews

Map of West Tennessee with blue location markers scattered across various towns and highways, including Jackson and areas near Oakfield, Trenton, and the Hatchie National Wildlife Refuge, highlighting the service area.

PROUDLY SERVING Jackson, TN

  • Bells
  • Brownsville
  • Dyersburg
  • Henderson
  • Humboldt
  • Huntingdon
  • Jackson
  • Lexington
  • Medina
  • Milan
  • Three Way
  • Trenton

Solace Plumbing, Heating, and Air is Proud to Offer Affordable Financing Options With Approved Credit. 

Contact Us Today to Start Saving!

Elevate your home effortlessly with our flexible financing solutions. Whether it’s repairs or installations, we have the perfect options for you. Contact Solace Plumbing, Heating, and Air today to find the ideal plan for your home in Jackson, TN!

Frequently Asked Questions About Furnace Repair

Most Recent Pins (41)

Conner Droke
Solace Heating and Air in Jackson, TN inspected a frozen HVAC unit. They identified leaks and oil buildup in the evaporator pan. The technician provided an estimate for a new system to the customer.
Pin Photo
Pin PhotoPin PhotoPin PhotoPin Photo
Conner Droke
Solace Heating and Air serviced an AC unit in Jackson, TN. They replaced a faulty capacitor in the condenser and identified low R-22 refrigerant levels. They advised the customer to consider unit replacement due to high refrigerant costs and provided an estimate upon request.
Air conditioner condenser fan with cordless drill on top
Air conditioner condenser fan with cordless drill on topHVAC capacitor and wiring inside condenser unitReturn air vent grille on textured ceilingHoneywell thermostat displaying indoor and outdoor tempsR22 refrigerant pressure gauge on HVAC unit
Conner Droke
Solace Heating and Air in Jackson, TN inspected an air conditioning unit that was not cooling. They found the blower motor working but the condenser was not connected properly. After correctly hooking up the condenser, they tested the system and confirmed it functioned as expected.
Air conditioner insulated refrigerant line damage close-up
Air conditioner insulated refrigerant line damage close-upRefrigerant pressure gauge measuring HVAC system psiAir conditioner control board wiring connections close-upHVAC control board wiring with wire connectorsHVAC control board with connected wiring in unit
Conner Droke
Solace Heating and Air inspected an air conditioning unit in Jackson, TN, and found it overcharged with Freon. They removed one and a half pounds of Freon, which improved the unit's operation and efficiency. The customer confirmed the unit worked better after the service.
Refrigerant manifold gauge measuring AC unit pressures
Refrigerant manifold gauge measuring AC unit pressuresFloor vent air temperature check with digital thermometerRefrigerant manifold gauge on HVAC unit readingsHVAC outdoor unit with opened panel and drill on topThermostat with inserted temperature probe and digital display
Conner Droke
Solace Heating and Air in Jackson, TN provides thorough HVAC tuneups. They inspect and clean the entire system, including capacitors, wiring, and control boards, ensuring all parts function properly. This detailed maintenance helps keep HVAC units running efficiently and reliably.
Trane XR outdoor air conditioner unit cleaning and inspection
Trane XR outdoor air conditioner unit cleaning and inspectionHVAC outdoor condenser unit with clean grille and wiringHVAC capacitor and wiring inside unit panelHVAC capacitor with wiring and metal housingFurnace unit with ventilation and piping in attic
Conner Droke
Solace Heating and Air performed a tuneup on a split heat pump in Bell, TN. They inspected the attic and outdoor unit, checked the capacitor, wiring, contactor boards, and connections. After cleaning dust from the system, they confirmed proper Freon levels and found no issues.
Split heat pump outdoor unit on concrete pad
Split heat pump outdoor unit on concrete padSplit heat pump outdoor unit with clean coilsHeat pump capacitor testing with multimeter probeClamp meter measuring air conditioning unit currentSplit heat pump attic unit with tool on top
Conner Droke
Solace Heating and Air performed a two-system tune-up in Jackson, TN. They inspected and cleaned both HVAC systems, replaced a faulty 455 capacitor in the upstairs split system, checked Freon levels, and ensured all components functioned properly.
HVAC blower motor inside unit with wiring connections
HVAC blower motor inside unit with wiring connectionsGas line and furnace connection in basement cavityAir conditioner outdoor unit with wiring and labelCapacitor replacement and system cleaning on split HVAC unitHVAC evaporator coil with heavy dust buildup
Conner Droke
Solace Heating and Air performed a six-system tune-up on a commercial building in Jackson, TN. They inspected wiring, capacitors, and drain lines, checked the attic and Samsung mini split air handler, and cleaned the outdoor units. All systems operated efficiently after the service.
Refrigerant pressure gauge on HVAC copper tubing
Refrigerant pressure gauge on HVAC copper tubingHVAC wiring bundle with technician hand adjusting wiresClamp meter measuring HVAC unit electrical currentSamsung mini split air handler wiring and capacitor check outdoorsAC capacitor testing with multimeter probes in HVAC unit
Conner Droke
Solace Heating and Air cleaned the vent motor pressure area to remove wasp blockage caused by cold outdoor temperatures. After cleaning, they tested the unit to ensure proper operation and found no issues. This service was performed in the local area.
Vent motor and wiring inside HVAC unit
Conner Droke
Solace Heating and Air diagnosed a faulty vent motor causing loud noise and pressure issues. After replacing the motor, the unit operated properly without any problems. This heating and air service ensures vent motors function correctly to maintain system performance. Location details are not specified.
Vent motor wiring and pressure switch inside HVAC unit
Vent motor wiring and pressure switch inside HVAC unitVent motor and pressure switch inside HVAC unitVent motor and control board wiring inside HVAC unit panel
Jared Coel
Solace Heating and Air replaced an inducer motor relay on a Goodman gas package unit in Jackson, TN, ensuring reliable heating during winter by verifying system operation post-service.
Check-in Location
Inducer motor relay component held during HVAC service
Inducer motor relay component held during HVAC serviceInducer motor relay for Goodman gas package unitInducer motor relay and wiring in Goodman unit
Jared Coel
A technician in Jackson, Tennessee inspected a Goodman gas package system that was not producing heat. They identified a dirty flame sensor as the problem, cleaned the sensor, and confirmed that the system was heating correctly.
Check-in Location
Flame sensor current measurement on Goodman gas system
Flame sensor current measurement on Goodman gas systemGoodman gas package flame sensor with dirt buildupGoodman gas package system flame sensor cleaningFlame sensor current reading on Goodman gas unit
Jared Coel
A technician inspected an Airease gas furnace in McKenzie, Tennessee that was not producing heat. The issue was traced to a locked gas meter, and the cause was explained to the customer.
Check-in Location
Gas meter with locked valve and padlock outdoors
Gas meter with locked valve and padlock outdoorsGas furnace limit switch with wiring connectionsGas meter with locked-off valve inside utility area
Jared Coel
Solace Heating and Air replaced a failed inducer motor, gas valve, and control board on a Goodman gas furnace in Jackson, Tennessee, verifying proper operation to ensure reliable heating during winter months.
Check-in Location
Goodman gas furnace inducer motor with wiring
Goodman gas furnace inducer motor with wiringGoodman furnace inducer motor with wiring connectionsGas furnace control board with wiring harnesses
Jared Coel
A technician in Linden, Tennessee inspected a York high-efficiency condensing furnace due to a strong odor. The source was traced to the condensate drain. To resolve the issue, the technician installed a drain trap to separate the furnace from the drain line.
Check-in Location
Condensate drain trap added to furnace system
Condensate drain trap added to furnace systemCondensate drain CO monitor on furnace coilCondensate drain inspection on furnace camera display
Jared Coel
Solace Heating and Air completed a combustion analysis on a propane gas package unit in Jackson, Tennessee. The technician confirmed the unit operates efficiently and burns cleanly, ensuring proper fuel use and system performance.
Check-in Location
Propane gas package unit burner flame inspection
Propane gas package unit burner flame inspectionCombustion analyzer measuring propane gas package unit pressurePropane gas package unit burner flame combustion analysis
Jared Coel
Solace Heating and Air inspected an Ameristar gas package system in Brownsville, Tennessee. Technicians found the unit operational but detected a weak blower motor capacitor. They replaced the capacitor to maintain proper heating function.
Check-in Location
Blower motor capacitor and wiring in HVAC system
Blower motor capacitor and wiring in HVAC systemBlower motor capacitor tested with digital multimeterElectrical meter testing on HVAC control panel
Jared Coel
Solace Heating and Air repaired a 20-year-old American Standard gas furnace in Brownsville, Tennessee. The technician replaced a faulty inducer motor and a weak blower capacitor. The system was tested and confirmed to be heating properly after the repair.
Check-in Location
American Standard furnace inducer motor and capacitor replacement
American Standard furnace inducer motor and capacitor replacementBlower motor capacitor and voltmeter testing setupGas furnace inducer motor and blower capacitor replacement
Jared Coel
Solace Heating and Air serviced gas logs in Jackson, Tennessee. The team cleaned the thermocouple, repaired a damaged thermostat wire, and confirmed proper thermocouple voltage to prepare for upcoming cold weather.
Check-in Location
Gas log thermostat wire with corrosion and wear
Jared Coel
A technician in Jackson, Tennessee inspected a Nordyne gas furnace that was not producing heat. They identified a weak blower capacitor and a low-reading flame sensor. The technician explained the issues and presented the customer with repair options.
Check-in Location
Blower capacitor current measurement on Nordyne furnace
Blower capacitor current measurement on Nordyne furnaceNordyne gas furnace flame sensors on workbenchNordyne gas furnace blower motor wiring and capacitor
Jared Coel
A technician in Jackson, Tennessee inspected two gas package HVAC systems with separate issues. The inspection included heat exchangers, blower motors, coil condition, and electronics. The technician completed a detailed assessment of both systems to determine their operational status.
Check-in Location
Gas package system rusted heat exchanger and wiring
Gas package system rusted heat exchanger and wiringGas package system heat exchanger rust damage close-upGas package system heat exchanger inspection with flashlight
Kein Hernandez
Solace Heating and Air replaced a blower motor and blower motor control board in Jackson, Tennessee. Technicians completed the repair and confirmed the equipment is working correctly. This service restored full function to the HVAC system.
Check-in Location
Blower motor control board with wiring in HVAC unit
Blower motor control board with wiring in HVAC unitBlower motor and control board label on HVAC unit
Conner Droke
Solace Heating and Air cleaned a dirty flame sensor on a heating unit in Dallas, Texas. The technician inspected the system and confirmed all functions operated efficiently after service.
Flame sensor cleaning on HVAC unit in Memphis
Flame sensor cleaning on HVAC unit in MemphisFlame sensor cleaning and control board wiring inside HVAC unitFlame sensor and gas valve inside furnace unit
Jared Coel
Solace Heating and Air replaced a faulty high limit switch on a two-month-old Ameristar unit in Sacramento, California. The part was under warranty and the repair restored proper system function.
High limit switch wiring on Ameristar HVAC unit
Conner Droke
Solace Heating and Air replaced a gas valve on a new American Standard unit in Philadelphia, Pennsylvania. They reset the pressure to 3.3 and verified that the heating system operated correctly after testing. The system showed no further issues at the time of service.
Gas valve and burner assembly in American Standard furnace
Conner Droke
A technician inspected a new gas floor heater in Lake Havasu City, Arizona, but could not complete testing because the connected propane tank was empty. Service will resume once the propane supply is restored.
Propane tank gauge showing empty on gas floor heater
Jared Coel
Solace Heating and Air installed a new floor furnace in Fresno, California. Technicians added new venting and thermostat wires. They tested the system and confirmed the furnace functions correctly.
Digital manometer measuring furnace draft pressure
Jared Coel
Solace Heating and Air repaired a Rheem gas furnace in Greenville, South Carolina. A damaged pressure tube caused heating failure. Technicians identified rodent damage to the tubing between the inducer motor and pressure switch. They replaced the tubing and restored full operation of the furnace.
Furnace control system label with model and serial info
Kein Hernandez
Solace Heating and Air replaced a failing blower motor on a 2014 Trane gas package system that had no heat. This heating repair service was completed in Jackson, Tennessee.
Check-in Location
Trane gas package system specifications label close-up
Kein Hernandez
Solace Heating and Air completed a fall maintenance check on a 2024 American Standard gas package system in Jackson, Tennessee. The technician confirmed that all components of the system are operating correctly. This service helps maintain energy efficiency and consistent performance through seasonal changes.
Check-in Location
2024 American Standard gas package current meter reading
2024 American Standard gas package current meter readingAmerican Standard gas package system label close-upDigital multimeter measuring HVAC electrical currentAmerican Standard gas package unit outdoor installation
Kein Hernandez
Solace Heating and Air replaced a recalled control board under warranty in Jackson, Tennessee. The replacement included both parts and labor at no additional cost. The service ensured the HVAC system continued to operate reliably and safely.
Check-in Location
Trane HVAC unit label with electrical specs and warnings
Trane HVAC unit label with electrical specs and warningsHeat pump outdoor unit with leaf debris on top
Jared Coel
A technician diagnosed a no-heat issue on a Trane gas furnace and identified a faulty hot surface igniter. The team replaced the igniter and confirmed the furnace is now heating correctly. This service was completed by Solace Heating and Air. Location data was not provided for this job.
Gas furnace hot surface igniter close-up inside unit
Jared Coel
Solace Heating and Air repaired a non-working Trane package system in an older unit in [City, State unavailable]. The technician identified a faulty inducer motor and a rusted burner assembly, then explained available repair options to restore heat and system function.
Rusted burner assembly inside Trane package system
Jared Coel
Solace Heating and Air completed fall heating maintenance on an Ameristar gas package system. The technician inspected the burners, inducer motor, igniter, and heat exchanger to ensure they were functioning properly. This service helps maintain system efficiency and supports reliable heating performance through the colder months. Location details were not provided.
Job link meter measuring electrical current on HVAC system
Jared Coel
Solace Heating and Air completed fall heating maintenance on a Trane gas package system in [City], [State]. The technician inspected the unit, found corrosion on the burner assembly, discussed repair options, and confirmed the system works properly for winter use.
Trane gas package burner assembly with corrosion buildup
Trane gas package burner assembly with corrosion buildupDigital clamp meter measuring microamps on rocks backgroundGas package system burner pressure test tool
Jared Coel
A technician inspected a Rheem gas package unit and found a rusted inducer motor causing a no-heat issue. The technician explained the problem and discussed repair options with the customer in Fort Smith, Arkansas.
Rheem gas package unit inducer motor rust damage
Rheem gas package unit inducer motor rust damageRheem gas package unit inducer motor rust buildupRheem gas package unit inducer motor rust damage
Jared Coel
Solace Heating and Air completed fall maintenance on a Bryant gas package system in North Carolina. Technicians cleaned rusted burners that were preventing ignition. They inspected the heat exchanger, inducer motor, and related components to confirm proper function before winter.
Burners and gas valve assembly with rust buildup
Burners and gas valve assembly with rust buildupGas package system burner with rust buildupBurner tube with rust buildup held by hand outdoors
Jared Coel
Solace Heating and Air completed fall maintenance on a Trane gas package system in North Carolina. Technicians removed a wasp nest from the inducer motor, inspected all heating components, and confirmed the unit operates correctly. The system is now ready for the colder season and functioning as expected.
Inducer motor current measurement on Trane gas package unit
Inducer motor current measurement on Trane gas package unitTrane gas package system heat exchanger with dirt buildupTrane gas package system heat exchanger coils close-up
Jared Coel
Solace Heating and Air replaced a recalled control board on an American Standard gas package unit in Denton, Texas. The team confirmed the unit now operates correctly with no remaining issues.
Control board replacement on American Standard gas unit
Control board replacement on American Standard gas unitAmerican Standard gas package unit control board replacementGas package unit control board with wiring harness
Jared Coel
A technician in Jackson, Tennessee replaced a damaged blower motor and furnace control board on a York gas furnace. The repair restored full heating system function and ensured proper airflow and safety. System performance was tested and confirmed after installation.
Check-in Location
Furnace control board with burnt circuit damage
Furnace control board with burnt circuit damageFurnace control board with wiring and componentsBlower motor in York gas furnace unit close-up
Drew Layton
Check-in Location
Check-ins - Reviews - Content - Ranking

It Was a Pleasure Serving You!



×

Schedule Now

Name
Address